Key features

  • Certifies copper cable for TIA category 5 through 6A
  • Shows Pass/Fail in 10 seconds, with full measurement details
  • Supports RJ45, M12D, and M12X connectors
  • Documents results with LinkWare™ PC
In stock
$13,446.99
FREE Shipping
30-day Returns
Product + Premium Care Plan
Premium Care Plan only (I already own the product)
No thanks

Product overview: Fluke Networks Industrial Ethernet DSX CableAnalyzer™ Kit

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

Studies show that half of Industrial Ethernet problems are caused by cabling. The DSX CableAnalyzer validates cable performance to TIA 1005-A and ISO 11801:3 standards, allowing industrial companies and machine builders to ensure compliance, start up faster, and reduce production down time.

The DSX CableAnalyzer works on cables running EtherNet/IP™, Profnet™, ModBus TCP™, EtherCAT, plus other protocols. It offers touchscreen project management, TIA Level IIIe accuracy, and advanced troubleshooting, all with integrated Wi-Fi and 8-hour battery life.

The kit includes the Versiv mainframe and remote units, a reference module, adapters, commonly used accessories, and a statement of calibration. 
 
 

Specifications: Fluke Networks Industrial Ethernet DSX CableAnalyzer™ Kit

Cable types
Shielded and unshielded pair LAN cablingTIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard link interface adapters
Permanent link adaptersPlug type: shielded RJ45
Optional Plug type: Tera
Channel AdaptersJack type: shielded RJ45
Optional Jack type: Tera, GG45
Test standards
TIACategory 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IECClass C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequencyDSX-5000: 1000 MHz
General specifications
Speed of AutotestDSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL)
Input protectionProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display5.7 in LCD display with a projected capacitance touchscreen
CaseHigh impact plastic with shock absorbing overmold
DimensionsMain Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
WeightMain Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote:Lithium ion battery pack, 7.2 V
Typical battery life:8 hours
Charge time*Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supportedEnglish, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
CalibrationService center calibration period is 1 year
Integrated Wi-FiMeets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental specifications
Operating temperature32°F to 113°F (0°C to 45°C)
Storage temperature-14°F to +140°F (-10°C to +60°C)
Operating relative humidity0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
VibrationRandom, 2 g, 5 Hz-500 Hz
Shock1 m drop test with and without module and adapter
SafetyCSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMCEN 61326-1
Performance specifications **
DSX-5000Category 6A/Class EA test modes (or lower link categories)Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modesExceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of twisted pair cabling1
 Without remoteWith remote
Range800 m (2600 ft)150 m (490 ft)
Resolution0.1 m or 1 ft0.1 m or 1 ft
Accuracy± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)
Propagation delay
 Without RemoteWith Remote
Range4000 ns750 ns
Resolution1 ns1 ns
Accuracy± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)
Delay skew
Range0 ns to 100 ns
Resolution1 ns
Accuracy± 10 ns
DC loop resistance test
Range0 Ω to 540 Ω
Resolution0.1 Ω
Accuracy± (1 Ω + 1 %)
Overload recovery timeLess than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

*Available in certain geographies currently

**Applies to accessories in the original product purchase

Models: Fluke Networks Industrial Ethernet DSX CableAnalyzer™ Kit

DSX2-5-IE-K1
DSX CableAnalyzer Industrial Ethernet Kit
Part#: 5081185
UPC#: 7 54082 14967 5
Includes:
  • (1) Versiv Mainframe and Remote
  • (2) DSX-5000 Copper CableAnalyzer Modules
  • Set of Cat 6A/Class EA Channel Adapters
  • Set of M12X adapters
  • Set of M12D adapters
  • Reference module*
  • (2) Headsets
  • (2) Hand strap
  • (2) Shoulder straps
  • Carry case
  • USB interface cable
  • (2) AC chargers
  • Integrated Wi-Fi
  • Statement of calibration
  • Getting started guide
*Since Permanent Link adapters are not included, the Reference Module is used to set-ref.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 54.45ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 1 out of 5 by from Bad service. My order was cancelled without notice. I email fluke and never got and answer why.
Date published: 2024-02-16
Rated 5 out of 5 by from My favorite and best cable tester available This tester when it came out had no other tester close to matching it. Its has a good size touchscreen for the main tester pkus an easy to read pass/fail remote, 10sec results of cable map(shows problem at main or remote sides, next, ps next, cable length, Cable shorts, so much more! Has different head attachments for RJ45 female and male connectors. Also we got the fiber optic heads yo switch to when working fiber optic (GREAT!)
Date published: 2022-10-06
Rated 5 out of 5 by from great device, excellent value for money What a useful device... Ive used it to device devices since the beginning of devices. Wow.... what a device
Date published: 2021-09-18
  • y_2024, m_3, d_12, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_3786405150772, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.39ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us page.
How can I help you today?